1.
Arq. bras. oftalmol ; 85(4): 344-350, July-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383831

ABSTRACT

ABSTRACT Purpose: To investigate the reduction in corneal endothelial cell density associated with gonioscopy-assisted transluminal trabeculotomy (GATT) in a short-term follow-up period. Methods: A retrospective analysis of the medical charts of patients with open-angle glaucoma who underwent gonioscopy-assisted transluminal trabeculotomy isolated or combined with phacoemulsification (phaco-gonioscopy-assisted transluminal trabeculotomy) was conducted. Patients who underwent phacoemulsification alone were included as controls. The endothelial cell density data (assessed using a specular microscope) before and at the first month after operation were collected and then compared. Results: Sixty-two eyes previously treated with gonioscopy-assisted transluminal trabeculotomy (gonioscopy-assisted transluminal trabeculotomy, n=39 eyes; phaco-gonioscopy-assisted transluminal trabeculotomy, n=23 eyes) fulfilled the inclusion criteria. The mean age of the study patients was 61.3 ± 18.4 years in the stand-alone gonioscopyassisted transluminal trabeculotomy group and 60.4 ± 11.9 in phaco-gonioscopy-assisted transluminal trabeculotomy group. Men comprised 66.6% of the patients in the isolated gonioscopyassisted transluminal trabeculotomy group and 56.5% of those in the phaco-gonioscopy-assisted transluminal trabeculotomy group. The mean visual field defects (mean deviation index) were -13.9 ± 9.2 and -10.3 ± 7.7 dB in the isolated gonioscopy-assisted and phaco-gonioscopy-assisted transluminal trabeculotomy groups, respectively. The patients in the former group presented a mean endothelial cell density reduction of 28.8 cells/mm² (1.31%; p=0.467). In the latter group, the mean endothelial cell density loss was 89.4 cells/mm² (4.36%; p=0.028). The control eyes (23 patients) presented a mean endothelial cell density change of 114.1 ± 159.8 cells/mm² (4.41%; p=0.505). The endothelial cell density reduction in the phaco-gonioscopy-assisted transluminal trabeculotomy group was not significantly different from that in the controls (p=0.81). Conclusions: Gonioscopy-assisted transluminal trabeculotomy appears to be a safe procedure for the corneal endothelial cell layer when performed either isolated or combined with cataract extraction in a short-term follow-up period.


RESUMO Objetivo: Investigar a redução na densidade celular endotelial corneana associada à trabeculotomia transluminal assistida por gonioscopia (GATT) em curto prazo. Métodos: Análise retrospectiva de prontuários médicos de pacientes com glaucoma de ângulo aberto que foram submetidos à trabeculotomia transluminal assistida por gonioscopia isolada ou combinada com facoemulsificação. Pacientes que foram submetidos à facoemulsificação isolada foram incluídos como controles. Dados da densidade celular endotelial corneana (avaliada através de microscópio especular) pré-operatória e ao primeiro mês pós-operatório foram coletados e comparados. Resultados: Sessenta e dois olhos que foram submetidos à trabeculotomia transluminal assistida por gonioscopia (trabeculotomia transluminal assistida por gonioscopia=39 olhos; faco com trabeculotomia transluminal assistida por gonioscopia=23 olhos) passaram pelos critérios de inclusão. A idade média dos pacientes estudados era 61,3 ± 18,4 anos no grupo trabeculotomia transluminal assistida por gonioscopia isolada e 60,4 ± 11,9 anos no grupo faco com trabeculotomia transluminal assistida por gonioscopia. Homens eram 66,6% do grupo trabeculotomia transluminal assistida por gonioscopia isolada e 56,5% do grupo faco com trabeculotomia transluminal assistida por gonioscopia. O defeito perimétrico médio (Mean Deviation) era -13,9 ± 9,2 dB e -10,3 ± 7,7 dB nos grupos trabeculotomia transluminal assistida por gonioscopia isolada e faco com trabeculotomia transluminal assistida por gonioscopia respectivamente. O grupo que fora submetido à trabeculotomia transluminal assistida por gonioscopia isolada apresentou redução média da densidade celular endotelial corneana de 28,8 células/mm² (1,31%; p=0,467). No grupo faco com trabeculotomia transluminal assistida por gonioscopia, a redução média da densidade celular endotelial corneana foi de 89,4 células/mm² (4,36%; p=0,028). Olhos controle (23 olhos) apresentaram redução média da densidade celular endotelial corneana de 114,1 ± 159,8 células/mm² (4,41%; p=0,505). A redução na densidade celular endotelial corneana no grupo faco com trabeculotomia transluminal assistida por gonioscopia não foi significativamente diferente do grupo controle (p=0,81). Conclusões: A trabeculotomia transluminal assistida por gonioscopia parece ser segura para a camada endotelial corneana em um curto prazo quando realizada de forma isolada ou combinada com cirurgia de catarata.

2.
Arq. bras. oftalmol ; 84(5): 454-461, Sept.-Oct. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1339209

ABSTRACT

ABSTRACT Purpose: The aim of this study was to compare corneal structure and endothelial morphological changes after uneventful phacoemulsification cataract surgery between type 2 diabetic and nondiabetic patients and to determine the preoperative and intraoperative factors that may predict greater endothelial cell density loss. Methods: Forty-five diabetic pa­tients (45 eyes) and 43 controls (43 eyes) with age-related cataract were enrolled in this prospective observational study. Corneal (thickness and volume) and anterior segment parameters were measured by Scheimpflug tomography; endothelial cell density and morphology (coefficient of variation of cell size, hexagonal cells) were recorded using noncontact specular microscopy. Patients were evaluated preoperatively and at one and six months after surgery. Univariate and multivariate linear regression analyses were performed to evaluate the relationship between demographic, clinical, ocular, and intraoperative parameters and postoperative endothelial cell density changes at six months. Results: Significant postoperative endothelial cell loss occurred one month after surgery in both groups (p<0.001), which remained stable until month 6; there were no differences between patients with and without diabetes mellitus at any time point. The mean postoperative central corneal thickness at one and six months did not change significantly from the mean preoperative value in either group (p>0.05). Multivariate linear regression analysis showed that older age (p=0.042) and higher cataract grades (p=0.001) were significantly associated with greater endothelial cell density reduction at six-month follow-up. Conclusion: This study showed that older age and denser cataracts might be associated with greater endothelial cell density reduction after cataract surgery. Other factors, such as diabetes mellitus and preoperative anterior segment parameters, did not influence postoperative changes in endothelial cell density.


RESUMO Objetivo: Comparar a estrutura da córnea e as alterações mor­fológicas endoteliais após cirurgia de catarata por facoemulsificação sem intercorrências entre pacientes com diabetes mellitus tipo 2 e não diabéticos; e determinar quais fatores pré e intra-operatórios relacionados com a maior redução da densidade celular endotelial. Métodos: Quarenta e cinco diabéticos (45 olhos) e 43 (43 olhos) controlos com catarata relacionada à idade foram incluídos neste estudo observacional prospectivo. Os parâmetros da córnea (espessura e volume) e do segmento anterior foram medidos pela tomografia Scheimpflug; a densidade e morfologia celular endotelial (coeficiente de variação do tamanho das células, células hexagonais) foram registrados usando microscopia especular não contato. Os pacientes foram avaliados no pré-operatório, 1 e 6 meses após a cirurgia. Foi realizada uma análise de regressão linear uni e multivariada para avaliar a relação entre os parâmetros demográficos, clínicos, oculares e intra-operatórios com a redução da densidade celular endotelial aos 6 meses. Resultados: Nos dois grupos houve uma perda significativa de células endoteliais ao 1º mês pós-ope­ratório (p<0,001), que permaneceu estável até ao 6º mês; sem diferenças estatisticas entre os grupos diabetes mellitus e não diabetes mellitus em qualquer avaliação. A espessura média da córnea no pós-operatório central aos 1 e 6 meses não mudou significativamente em relação ao valor médio pré-operatório nos dois grupos (p>0.05). A análise de regressão multivariada linear mostrou que a idade avançada (p=0.042) e os graus mais elevados de catarata (p=0.001) foram significativamente associados à maior redução densidade celular endotelial aos 6 meses de seguimento. Conclusão: Este estudo mostrou que a idade avançada e as cataratas mais densas podem predispor a uma maior redução densidade celular endotelial após a cirurgia de catarata. Outros fatores, como diabetes mellitus e parâmetros pré-operatórios do segmento anterior, não influenciaram significativamente as alterações pós-operatórias da densidade celular endotelial.

3.
Arq. bras. oftalmol ; 81(4): 310-315, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-950468

ABSTRACT

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodology. Subjective comfort, visual acuity, central corneal thickness, endothelial cell count, and corneal-compensated intraocular pressure were evaluated. The follow-up period was one year. Results: Contact lens use was discontinued in 3 patients, thus leaving 24 eyes from 8 females and 7 males for analysis. The fitting characteristics were optimal in terms of lens position and movement. Statistically significant improvements were found in the best spectacle-corrected vision from before fitting to the visual acuity after fitting (p<0.001). Moreover, the patients reported high subjective comfort ratings and usage times (12.98 ± 2.3 hours/day). After one year of wear, visual acuity, subjective comfort, and usage time were maintained. No statistically significant adverse changes developed in the corneas over this period. Conclusion: Corneoscleral contact lenses with a multi-aspherical geometry design provide optimal visual acuity, improved comfort, and prolonged usage times in patients with irregular corneas after LASIK.


RESUMO Objetivo: Descrever os resultados do ajuste de lentes de contato corneoesclerais com geometria multiasférica em pacientes com córneas irregulares após cirurgia de ceratomileuse in situ assistida por laser (LASIK). Métodos: Esta foi uma série retrospectiva de 18 pacientes (idade, 26-38 anos) selecionados a partir de um banco de dados de uma clínica oftalmológica. Os participantes foram escolhidos ao manifestaram acuidade visual insatisfatória com suas lentes de contato ou óculos atuais depois de terem sido submetidos à LASIK para correção de miopia. Todos os pacientes receberam lentes de contato corneoesclerais projetadas para corrigir irregularidades na superficie da córnea. Um conjunto diagnóstico de prova foi usado para a adaptação e as avaliações foram feitas de acordo com uma metodologia padronizada. O conforto subjetivo, a acuidade visual, a espessura central da córnea, a contagem de células endoteliais e a pressão intraocular compensada da córnea foram avaliados. O período de acompanhamento foi de um ano. Resultados: O uso de lentes de contato foi descontinuado em 3 pacientes, deixando 24 olhos de 8 mulheres e 7 homens para análise. As características de adaptação foram ótimas em termos de posição e movimento da lente. Melhorias estatisticamente significativas foram encontradas na melhoria da visão corrigida por óculos antes de se ajustar a acuidade visual após a adaptação (p<0,001). Além disso, os pacientes relataram altos índices subjetivos de conforto e tempo de uso (12,98 ± 2,3 horas/dia). Após um ano de uso, a acuidade visual, o conforto subjetivo e o tempo de uso foram mantidos. Não houve alterações adversas estatisti­camente significativas nas córneas ao longo deste período. Conclusão: As lentes de contato corneoesclerais com projeto geométrico multiasférico proporcionam acuidade visual ideal, maior conforto e tempo de uso prolongado em pacientes com córneas irregulares após o LASIK.


Subject(s)
Humans , Adult , Contact Lenses, Hydrophilic , Keratomileusis, Laser In Situ/adverse effects , Corneal Wavefront Aberration/etiology , Myopia/surgery , Visual Acuity , Retrospective Studies , Follow-Up Studies , Corneal Topography , Corneal Wavefront Aberration/rehabilitation , Corneal Pachymetry
4.
Arq. bras. oftalmol ; 77(6): 382-387, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-735805

ABSTRACT

Purpose: To describe quantitative and qualitative features of eyes with advanced bullous keratopathy assessed using ultrasound biomicroscopy, before and after anterior stromal puncture (ASP) or amniotic membrane transplantation (AMT) procedures to relieve chronic pain. Methods: The present descriptive comparative study included 40 eyes of 40 patients with chronic intermittent pain due to bullous keratopathy who were randomly assigned to one of the two treatments (AMT or ASP). Ultrasound biomicroscopy (Humphrey, UBM 840, 50 MHz transducer, immersion technique) was used, and a questionnaire about pain intensity was completed preoperatively and postoperatively at days 90 and 180, respectively. Exclusion criteria were age<18 years, presence of concurrent infection, ocular hypertension, and absence of pain. Results: In a 180-day follow-up, the AMT group exhibited mean central corneal thickness (CCT), 899.4 µm preoperatively and 1122.5 µm postoperatively (p<0.001); mean epithelial thickness (ET), 156.4 µm preoperatively and 247.8 µm postoperatively (p<0.001); and mean stromal thickness (ST), 742.9 µm preoperatively and 826.3 µm postoperatively (p=0.005). The ASP group exhibited mean CCT, 756.7 µm preoperatively and 914.8 µm postoperatively (p<0.001); mean ET, 102.1 µm preoperatively and 245.2 µm postoperatively (p<0.001); and mean ST, 654.6 µm preoperatively and 681.5 µm postoperatively (p<0.999). Correlations between CCT and pain intensity in the AMT group (p=0.209 pre- and postoperatively) and the ASP group (p=0.157 preoperatively and p=0.426 at the 180-day follow-up) were not statistically significant. Epithelial and stromal edema, Descemet’s membrane folds, epithelial bullae, and the presence of interface fluid were frequently observed qualitative features. Conclusion: CCT increased over time in both groups. The magnitude of CCT did not correlate with pain intensity in the sample studied. The presence of interface ...


Objetivo: Descrever as características quantitativas e qualitativas da biomicroscopia ultrassônica (UBM) em olhos com ceratopatia bolhosa avançada, antes e após os procedimentos de punção estromal anterior (ASP) ou transplante de membrana amniótica (AMT) para alívio de dor crônica. Métodos: Estudo comparativo descritivo incluindo 40 olhos de 40 pacientes com dor crônica intermitente devido a ceratopatia bolhosa, randomizados em duas modalidades de tratamento (AMT e ASP). Biomicroscopia ultrassônica (Humphrey, UBM 840, transdutor de 50 MHz, técnica de imersão) foi utilizada, e um questionário de avaliação da intensidade da dor foi aplicado no pré-operatório, e após 90 e 180 dias de pós-operatório. Critérios de exclusão foram: idade abaixo de 18 anos, presença de infecção, hipertensão ocular, e ausência de dor. Resultados: No seguimento de 180 dias, o grupo Transplante de membrana amniótica apresentou: média da espessura corneana central (CCT): 899,4 µm (pré), 1.122,5 µm (pós-operatório) (p<0,001); média da espessura epitelial (ET): 156,4 µm (pré), 247,8 µm (pós-operatório) (p<0,001); média da espessura estromal (ST): 742,9 µm (pré), 826,3 µm (pós-operatório) (p=0,005), e, grupo ASP apresentou: CCT média: 756.7 µm (pré), 914,8µm (pós-operatório) (p<0,001); ET média: 102,1 µm (pré), 245,2 µm (pós-operatório) (p<0,001); ST média: 654,6 µm (pré), 681.5 µm (pós-operatório) (p<0,999). A correlação entre intensidade da dor e espessura corneana central no grupo AMT (p=0,209 pré e pós-operatórios) e no grupo ASP (p=0,157 pré-operatório e p=0,426 aos 180 dias de seguimento) não foi significativa. Edema epitelial e estromal, dobras na membrana de Descemet, bolhas epiteliais, e presença de fluido na interface foram características qualitativas frequentemente observadas. Conclusão: A espessura corneana central aumentou ao longo do tempo em ambos os grupos. A magnitude da espessura corneana central não interfere na intensidade da dor ...


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Corneal Diseases/surgery , Corneal Diseases , Amnion/transplantation , Blister/surgery , Corneal Pachymetry , Corneal Stroma/pathology , Corneal Stroma/surgery , Corneal Stroma , Endothelium, Corneal/pathology , Endothelium, Corneal/surgery , Endothelium, Corneal , Eye Pain/surgery , Microscopy, Acoustic/methods , Pain Measurement , Postoperative Period , Preoperative Period , Punctures , Pain Management/methods , Palliative Care/methods , Statistics, Nonparametric , Surveys and Questionnaires , Time Factors , Treatment Outcome
5.
Arq. bras. oftalmol ; 74(3): 195-200, May-June 2011. ilus
Article in Portuguese | LILACS | ID: lil-598314

ABSTRACT

OBJETIVO: Relatar os resultados da ceratoplastia endotelial com desnudamento da Descemet (DSEK) utilizando o dispositivo TAN EndoGlideTM para facilitar a introdução da membrana endotelial. MÉTODOS: Série de casos consecutivos, prospectiva. Foram incluídos 9 pacientes com edema corneano secundário à disfunção endotelial. Melhor acuidade visual corrigida, refração, astigmatismo ceratométrico, espessura corneana central, densidade das células endoteliais e complicações foram analisadas após seguimento de seis meses. RESULTADOS: Houve melhora do edema de córnea e da visão em 7 pacientes (77,78 por cento). A melhor acuidade visual corrigida ficou entre 20/40 e 20/200. A densidade endotelial média após 6 meses variou entre 1.305 céls/mm² e 2.346 céls/mm² com média de perda de 33,14 por cento. Desprendimento de parte do enxerto ocorreu em 1 olho (11,11 por cento), falência primária do transplante endotelial em 2 olhos (22,22 por cento). CONCLUSÃO: O dispositivo TAN EndoGlideTM facilita a introdução do enxerto na ceratoplastia endotelial com desnudamento da Descemet.


PURPOSE: To report the results of Descemet stripping endothelial keratoplasty (DSEK) using the TAN EndoGlideTM device to facilitate the insertion of the endothelial membrane. METHODS: Prospective clinical study that included nine patients presenting corneal edema secondary to endothelial dysfunction. Best corrected visual acuity, refraction, central corneal thickness, endothelial cell density and complications were analyzed after a six-month follow-up. RESULTS: There was a significant improvement in the corneal edema and visual acuity in 7 patients (77.78 percent). The best corrected visual acuity ranged between 20/40 and 20/200. The average density of endothelial cells in six months varied between 1,305 cells/mm² and 2,346 cells/mm² with an average loss of 33.14 percent cells. Detachment of part of the graft was observed in one eye (11.11 percent) and primary failure of the endothelial transplantation occurred in 2 eyes (22.22 percent). CONCLUSION: The device TAN EndoGlideTM facilitates the introduction of the graft in Descemet stripping endothelial keratoplasty.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Corneal Diseases/surgery , Descemet Membrane/surgery , Descemet Stripping Endothelial Keratoplasty/instrumentation , Endothelium, Corneal/transplantation , Descemet Stripping Endothelial Keratoplasty/methods , Follow-Up Studies , Prospective Studies , Treatment Outcome , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL